Evaluation of Manufacturing Robustness for a Biodegradable Subcutaneous Implant Containing Bictegravir for HIV Prevention
Year: 2023
Type: article
Abstract: According to World Health Organization (WHO), the global impact of human immunodeficiency virus (HIV) infection remains a significant concern, necessitating the development of effective prevention strategies. Oral pre-exposure prophylaxis (PrEP) is one method available for HIV reducing the risk of HIV transmission. However, several barriers such as patient adherence and persistence to product use have limited its widespread uptake. To address this challenge, a long-acting injectable PrEP product was recently approved by the FDA, as long-acting products are associated with improved adherence and compliance. Toward this end, Research Triangle Institute (RTI) International is currently developing a long-acting HIV PrEP product in the form of a biodegradable implant made from polycaprolactone (PCL), which incorporates the antiretroviral drug Bictegravir (BIC). This thesis focuses on the characterization of the BIC-loaded PCL implants and the validation of manufacturing processes to support technology transfer activities. Two high-performance liquid chromatography (HPLC) analytical procedures for both assay and dissolution study were qualified to be accurate and reliable. Formulation paste containing Bictegravir and castor oil was prepared and loaded into PCL tubes to fabricate the implants at Magee-Womens Research Institute (MWRI). Then, these implants were characterized and compared with those from RTI to validate the impact of different processing parameters. The implants consistently achieved the target drug loading of 120 mg of Bictegravir per implant, with uniform distribution within individual implants as well as between implants. Notably, significant differences in the in-vitro release profiles were observed between the two sets of implants after 2 weeks during the dissolution study, which indicated the importance of sealing integrity in ensuring reproducibility and quality of implants. Consequently, further investigations into testing the sealing integrity should be developed. In conclusion, this thesis employed qualified HPLC methods for the characterization of BIC-loaded PCL implants. The cross-lab evaluation of implants underscored the significance of implant sealing integrity as a crucial processing aspect, emphasizing the need for ongoing research to investigate the testing and validation of sealing integrity.
Author: Chen, Yu-Chieh
Institution: University of Pittsburgh
Language: English
Subfield: Pharmaceutical Science
Domain: Life Sciences
Open Access status: green
OpenAlex ID: W7056643196
