Work

Proposed design criteria on thin-wall precast panels for hydraulic concrete structures

Year: 2003
Type: report
Abstract: Chapter 1 Introductionreport is intended to provide suggested criteria for the design of precast concrete hydraulic structures. of innovative structures.Coordination with this work unit primarily entails ensuring that those team members are aware of the methods and criteria that are suggested in this report. 1-2 DesignDesign of the precast elements for the Olmsted and Braddock Projects was performed using existing Corps criteria, supplemented by criteria from the American Concrete Institute (ACI 1999), the American Association of State Highway and Transportation Officials (AASHTO 1998), and the Precast/Prestressed Concrete Institute (PCI 1992).Actual design of the precast sections to be constructed was performed using a combination of design assumptions, hand-calculations, and computer analyses.The designs performed were rational and resulted in structures that were economically feasible and constructible; however, the process used points to a need for developing specific criteria.With regard to the criteria themselves, the use of criteria from ACI, AASHTO, and PCI is a sound process to employ, although approval from higher authority may be required if the design issue has not been addressed by Corps criteria.These existing standard guidelines generally address precast components for building or bridge structures.It may be inappropriate in some cases to directly use these guidelines for navigation structures without due considerations of special conditions and requirements, such as durability and crack control requirements, and fatigue resistances for permanently floating lock guide walls.For these types of cases, there is a need to first determine whether the criteria in these other codes must be altered, or if they can be used as they are presented.Establishing these issues in official Corps guidance would alleviate the need to obtain approvals for each project.Some discussion regarding design philosophy is contained in Appendix A and may be helpful in making decisions whether or not to use certain codes.Supplemental information presented in other appendixes includes a summary of lessons learned from Braddock Dam construction (Appendix B), a discussion of dimensional tolerances of precast components (Appendix C), example calculations for the design of precast stay-in-place form panels for lock walls (Appendix D), four detailed design examples from recent Corps projects (Appendix E), and a discussion of some alternate design methods (Appendix F). Rehabilitation:• Resurfacing of lock chamber wall and river wall surfaces.• Resurfacing of pier vertical surfaces.• Resurfacing of guide and guard walls.• Resurfacing of valve wells and pits.• Rebuilding of lock ladder, mooring hook, and floating mooring bit recesses. New construction:• Float-in or lift-in base units for gated dams.• Float-in or lift-in base units for lock monoliths.• Precast beams for guide and guard walls.• Floating guide walls.• Stay-in-place forms for lock walls (with or without wall armoring).• Stay-in-place forms for dam piers (with or without nosing steel).• Baffle blocks or other spillway roughening elements.• Trunnion girders for gated dams.• Tailrace panels for dam spillways.• Scour protection.• Boat sections for channels.• Approach walls, both floating and fixed.• Storm surge barriers.• Mooring cells.• Pump stations and concrete barriers for flood control.• Paving blocks, including those for lock floors.
Language: English
Open Access status: green
OpenAlex ID: W7166405521
Cites: 8
Cited by:
Related to: 10