Work

Supplementary calibration and validation dataset for "Correcting Time Offsets and Enclosure-Induced Measurement Distortions in LiDAR–Camera Systems"

Year: 2026
Type: supplementary-materials
Abstract: Simulation code and results derived from the calibration method presented in "Correcting Time Offsets and Enclosure-Induced Measurement Distortions in LiDAR–Camera Systems" (Ranasinghe et al., Measurement, 2026, https://doi.org/10.1016/j.measurement.2026.122285). This repository extends the flywheel-based temporal calibration approach with an improved target design. A ROS 1 Noetic / Gazebo simulation compares the original v1 target (single 60° sector with an index feature) against a corrected v2 design (solid centre, two cut-outs at 60°/25°), evaluating angle-estimation accuracy before physical fabrication. Across three tested configurations (5 RPM with column, 10 RPM with column, 5 RPM without column; 900 frames total), the v2 design achieved mean angular errors between 0.215° and 0.394°, with results detailed in the included comparison report. Evaluates simulated range-based angle recovery only; does not validate Livox hardware/firmware timestamp behaviour. Code: https://github.com/maninka123/livox-flywheel-calib-sim
Institution: UNSW Sydney
Language: English
Open Access status: green
OpenAlex ID: W7202280337
Cites:
Cited by:
Related to: 10