Work

Real-Time Monitoring of Implantable Pumps

Year: 2025
Type: article
Abstract: Implantable drug delivery pumps administer insulin, intrathecal baclofen, intrathecal morphine, chemotherapeutic agents,and other therapeutics directly to target anatomical sites over months or years of continuous operation. The clinicalconsequences of pump malfunction range from therapy interruption to life-threatening overdose, and the diagnosticchallenge of distinguishing true device failure from underlying disease progression has historically depended on clinicalassessment, blood levels, and invasive device interrogation at scheduled follow-up visits. Real-time monitoring ofimplantable pumps through telemetry, sensor integration, and algorithmic anomaly detection addresses this diagnosticgap by providing continuous device performance visibility to clinicians and patients, enabling earlier detection of devicemalfunction, catheter occlusion, battery depletion, and delivery accuracy drift than periodic assessment provides. Thisstudy presents the Implantable Pump Monitoring Assessment Framework (IPMAF), evaluating five monitoringapproaches -- embedded telemetry with periodic data upload (ETM-PDU), continuous cloud-based pump telemetry withthreshold alerting (CCT-TA), multi-sensor fused monitoring with AI anomaly detection (MSF-AI), closed-loop integratedsensing with delivery algorithm adjustment (CLI-DAA), and federated cross-patient pump performance analytics(FCP-PPA) -- across four implantable pump contexts: insulin pumps, intrathecal baclofen/morphine pumps, hepaticarterial chemotherapy pumps, and emerging closed-loop neurological drug delivery systems. Performance was scoredusing the Pump Monitoring Effectiveness Score (PMES), a weighted composite of fault detection sensitivity (0.30), alertlead time (0.20), false alert management (0.20), patient-provider workflow integration (0.15), and privacy and datasecurity (0.15). Multi-sensor fused monitoring with AI anomaly detection achieved the highest PMES (0.887) through thebest fault detection sensitivity (0.940) and strong alert lead time (0.920). Closed-loop integrated sensing ranked second(0.878) with the best alert lead time (0.940). Continuous cloud-based telemetry (0.872) provides broadly applicablemonitoring. Embedded telemetry (0.851) remains the regulatory baseline. Federated cross-patient analytics (0.839)supports population-scale performance surveillance.
Language: English
Open Access status: diamond
OpenAlex ID: W7203607364
FWCI:
Cites: 4
Cited by:
Related to: 10