Self-collected versus clinician-collected specimens for chlamydia and gonorrhoea detection: Diagnostic agreement and acceptability
Year: 2026
Type: article
Study design: Observational Study
Abstract: Self-collection of specimens for sexually transmitted infection testing has been proposed as a strategy to improve screening uptake, reduce clinic workload and enhance patient autonomy, yet its diagnostic performance compared with clinician-collected specimens requires validation in diverse clinical settings. This diagnostic accuracy research evaluated the agreement between self-collected and clinician-collected vulvovaginal swabs (women) or first-void urine specimens (men) for the detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) by nucleic acid amplification testing, and assessed participant acceptability of self-collection. The research was conducted at a sexual health clinic in Lecce, Italy, between June 2023 and May 2024, and is reported in accordance with the STARD 2015 guideline. A total of 378 consecutive attendees provided paired self-collected and clinician-collected specimens, which were tested on the same NAAT platform (Abbott Alinity m STI assay). CT was detected in 71 self-collected specimens (18.8%) and 70 clinician-collected specimens (18.5%); NG was detected in 40 (10.6%) and 43 (11.4%) respectively. For CT, the positive agreement was 95.7% (95% CI 87.8-99.1), the negative agreement was 98.7% (96.7-99.6) and the overall kappa was 0.93 (0.88-0.98). For NG, the positive agreement was 88.4% (74.9-96.1), the negative agreement was 99.4% (97.9-99.9) and the kappa was 0.90 (0.83-0.97). Among participants who completed the acceptability questionnaire (n = 362), 87.4% stated they would choose self-collection again, 91.2% found it easy to perform and 72.8% preferred it to clinician collection. Confidence in specimen quality was lower (68.3%), and preference for self-collection was stronger among women than men (78.4% vs 65.1%, p = 0.006). These findings demonstrate that self-collected specimens achieve near-equivalent diagnostic performance to clinician-collected specimens for CT and NG detection by NAAT and are highly acceptable to patients, supporting their routine implementation in Italian sexual health services.
Authors: Zara Guidetti, Umberto Insalaco
Institution: University of Salento
Language: English
Subfield: Microbiology
Field: Immunology and Microbiology
Domain: Life Sciences
Open Access status: bronze
OpenAlex ID: W7204228590
