Interfacial Coating-Induced Charge Transport Regulation and Insulation Performance of HVDC Cable Joint Interfaces

Year: 2026
Type: conference-paper
Abstract: The XLPE/SiR interface in HVDC cable joints is vulnerable to microscopic voids, conductivity mismatch, and space-charge accumulation. This study compares double-layer XLPE/SiR specimens with and without silicone-grease coating at 30°C under interfacial preloads of 0, 0.2, and 0.4 MPa, using radial DC breakdown, DC conductivity, and space-charge measurements. At these preload levels, coating increases the characteristic radial DC breakdown field strength by 2.91%, 4.95%, and 5.89%, respectively. Conductivity measurements over 3-40 kV/mm and space-charge maps indicate improved interfacial electrical continuity and weakened charge accumulation near the XLPE/SiR boundary after coating. These results suggest that silicone grease is not only an assembly lubricant but also a functional interfacial layer that regulates charge transport and improves the insulation performance of HVDC cable joint interfaces within the tested preload window.