Noise-induced oscillations and coherence resonance in the hierarchical voltage control: MATLAB/Simulink models, scripts and parameters
Year: 2026
Type: software
Abstract: This record contains the MATLAB and Simulink models, simulation scripts and parameter sets that reproduce all the results reported in the article "Noise-induced oscillations and coherence resonance in the hierarchical voltage control". The work identifies noise-induced oscillations (NIO) and coherence resonance (CR) — phenomena well established for excitable systems in physics and chemistry — as the dominant mechanism behind the persistent slow voltage oscillations (0.01–0.1 Hz) that transmission system operators observe at specific network nodes. These oscillations are distinct from electromechanical oscillations and cannot be removed by re-tuning the secondary voltage controllers. The models implement the classical hierarchical voltage control scheme in discrete time, which is essential to reproduce the phenomenon: the generator and its reactive power control loop are discretised with a zero-order hold, the secondary PI regulator with the Tustin method, and a unit delay is applied to the pilot bus measurement. Continuous-time formulations of secondary voltage control, as commonly used in the literature, are structurally unable to reproduce these oscillations. Two test systems are included, both built on a two-generator network feeding a common pilot bus behind a grid equivalent: All-synchronous case. Sensitivity sweeps over the measurement noise intensity, the proportional and integral gains of the secondary voltage control, the network coupling and the sampling period. The sampling period, the noise intensity and the integral gain are shown to dominate the oscillation amplitude, partly through aliasing of the white measurement noise above the Nyquist frequency. Hybrid case. One synchronous generator is replaced by a 150 MVA wind farm operating at a fixed power factor, reflecting current operating practice for renewable plants. The oscillations intensify, because renewable intermittency adds an intrinsic noise source that cannot be removed by filtering. Contents: Simulink models of both configurations, the white-noise generator and its downsampling routine, the scripts that compute the modal metrics (natural frequency, damping ratio, peak frequency of the least-damped discrete eigenvalue) and the Bode and time-domain responses, the complete system and controller parameter sets, and the scripts that regenerate every figure and table of the article. A README file states the MATLAB and Simulink versions required and the order in which the scripts must be run.
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7207756397