Work

Design Basis Accident: Military Action Against Nuclear Facilities — Formal Accident Description and Design Requirements

Year: 2026
Type: report
Abstract: The formal accident description for military action against nuclear power facilities, issued under the DBA-MA International Framework. It postulates military operations by a hostile state and describes the accident as four phases: preparation, transition, sustained operation in the Autonomous Safe Shutdown Condition, and recovery, including the reassessment of a plant after hostile occupation. It defines the Autonomous Safe Shutdown Condition and its required characteristics, sets design-basis durations by facility class (not less than two years for large light-water reactors; a 72-hour class floor for near-term integral light-water small modular reactors), states the acceptance criteria, and gives the seven governing engineering principles with the categories of specific engineering requirements they generate. It is an independent proposal written in the vocabulary of the IAEA standards; it is not an IAEA publication.
Language: English
Open Access status: green
OpenAlex ID: W7214194841
Cites: 4
Cited by: 3
Related to: 10