Year: 2025
Type: article
Abstract: The Tamansari Row Houses in Bandung City are part of a relocation and slum revitalization program aimed at providing more organized, healthy, and decent housing for affected communities. Currently, the facility does not have a grey water treatment system. Grey water generated from bathing, laundry, and kitchen activities contains harmful pollutants that could contaminate the Cikapundung River if discharged directly. Therefore, it is necessary to design a grey water treatment plant (WWTP) with the potential reuse of the treated effluent for plant irrigation. The peak grey water flow rate was calculated at 144.872 m³/day, representing 70% of the peak domestic wastewater flow. Grey water characteristics showed a pH of 7.83; BOD of 46.60 mg/L; COD of 134.66 mg/L; TSS of 46 mg/L; oil and grease of 4 mg/L; ammonia of 6.28 mg/L; and total coliform of 8,400 counts/100 mL. The selection of the treatment alternative was carried out using descriptive analysis and the Weighted Ranking Technique (WRT). The selected treatment train consists of an oil and grease separator, Anaerobic Baffled Reactor (ABR), disinfection unit, and storage tank.
Source: Jurnal Serambi Engineering
Institution: Institut Teknologi Nasional Bandung
Language: English
Subfield: Waste Management and Disposal
Field: Environmental Science
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $32
OpenAlex ID: W7216916632