Work

Biomechanical Insights into Robotic-Assisted UKA vs. Conventional UKA: Trends in Fracture Resistance and Patterns

Year: 2026
Type: article
Abstract: Purpose: To compare load to failure and fracture morphology between conventional and robotic-assisted medial unicompartmental knee arthroplasty (UKA) and assess their association with tibial cortical index. Methods: Sixteen cadaveric specimens underwent conventional or robotic-assisted UKA (eight per cohort), with a different surgeon performing each technique. Isolated tibiae underwent axial compression at 1 mm/s until fracture. Exploratory regression assessed associations between radiographic cortical index and load to failure, adjusting for cohort. Results: Mean load to failure was 3623 ± 1757 N for robotic-assisted and 3619 ± 1640 N for conventional UKA (p = 0.996). Each 0.01 increase in AP and lateral cortical indices was associated with increases of 236.9 N and 277.8 N, respectively (both p < 0.001). Cohort membership was not significantly associated with failure load after adjustment. Fracture morphology differed descriptively. Conclusions: No significant difference in load to failure was detected; equivalence cannot be inferred. Higher cortical indices were associated with greater failure loads. Conventional technique confounding precludes attributing fracture patterns to robotic assistance, and these laboratory findings do not establish clinical fracture risk.
Source: Biomechanics
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: gold
Estimated APC paid: $1,207
OpenAlex ID: W7222931007
FWCI:
Cites: 29
Cited by:
Related to: 10