Work

Automated tracking of the tricuspid valve plane in long-axis cine images with a 2-step deep learning pipeline

Year: 2020
Type: conference-paper
Abstract: PurposeRight ventricular (RV) dysfunction is associated with increased morbidity and mortality in patients with varied cardiovascular diseases 1 , and it is commonly assessed by echocardiography, by measuring the tricuspid annular plane systolic excursion (TAPSE) and the peak diastolic velocity (RV e') of tricuspid annular (TA) motion 2 .However, very small changes in beam angle and changes in imaging window can significantly impact the evaluation of RV size and function 3 .Cardiovascular magnetic resonance (CMR) is not clinically utilized to measure such parameters but it is considered the reference standard for cardiac volume assessment.Only a few studies were reported to track the TA motion, but still required manual initialization or adjustment 4 .In this study we have developed a fully automated, fast and accurate method for TA motion tracking in long-axis cine images of the 4-chamber view, with a 2-step deep learning pipeline.This builds on our recent work to track the mitral valve 5 , with a similar deep learning pipeline. MethodsA group of 120 patients (54 females, age 55.6±14.7 years), scanned on a 1.5T clinical scanner for diverse clinical indications were retrospectively enrolled in an IRB-approved study.Four chamber cines were acquired with a balanced steady-state-freeprecession sequence with 30 timeframes per cardiac cycle, spatial resolution was 2x2x8 mm 3 , TR/TE/Θ: 3ms/1.5ms/60º.The software Segment 6 was used to manually annotate the TA points in all patient data as a reference.A residual neural framework of 50 layers (ResNet50) 7 was adapted to perform a regression task for both points in each image, using MATLAB Deep Learning Toolbox.The method used two trained networks and followed a 2-step deep learning pipeline.Step 1 used a trained network to predict the TA points in the first time frame of the cine series, with an accuracy sufficient to use the location of the TA points to reorient the long-axis cines into a standardized orientation, as part of the pre-processing.This step standardized the input image with a fixed size, cropping, resolution and heart orientation.Step 2 used another trained network to locate the TA points in all pre-processed frames, with a high accuracy, which were then reconverted to their original coordinates.The dataset was randomly split into two sets: 94 subjects for training and validating the neural network, and 26 test subjects for evaluating performance.
Language: English
Open Access status: green
OpenAlex ID: W7225212439
FWCI:
Cites: 8
Cited by:
Related to: 10