Evaluation of a parachute load distribution measuring system during low altitude drop tests
Year: 1969
Type: article
Abstract: In conjunction with the low-altitude preflight drop test phase of the NASA Supersonic High-Altitude Parachute Experiments (SHAPE) program, canopy-load-distribution measurements were made on each of three types of parachute during deployment (by means of a mortar) from an aircraft-dropped payload.Loads were measured with miniature load cells at various locations on the canopies and in the suspension lines of 30-and 40-footdiameter (9.14 and 12.19 meters) parachutes, with a total of seven measurements of this type being made on each of seven instrumented parachute drops.Out of a total of 49 such individual measurement attempts, there were six individual load-cell problems, which included one of lead-wire breakage during parachute deployment.Total parachute load measurements were also made during each test by means of a tensiometer in the main riser line.In addition, for the total parachute instrumentation program, data from approximately 40 percent of the channels were not obtained due apparently to onboard telemetry malfunction.A commercially available stretch cable was used in the hard wire data transmission link between all transducers and their corresponding telemetry channels in the payload.This cable, which required a pull of about 1 pound (4.45 newtons) for a 25-percent stretch, functioned in an excellent manner during all parachute drop tests.