A location science model for the placement of POC CD4 testing devices as part of South Africa's public healthcare diagnostic service delivery model
Year: 2015
Type: dissertation
Abstract: ENGLISH ABSTRACT: South Africa has a severe HIV (human immunodeficiency virus) burden and the management of the disease is a priority, especially in the public healthcare sector. One element of managing the disease, is determining when to initiate an HIV positive individual onto anti-retroviral therapy (ART), a treatment that the patient will remain on for the remainder of their lifetime. For the majority of HIV positive individuals in the country, this decision is governed by the results of a CD4 (cluster of differentiation 4) test that is performed at set time intervals from the time that the patient is diagnosed with HIV until the patient is initiated onto ART. A device for CD4 measurement at the point of care (POC), the Alere PIMA™, has recently become commercially available. This has prompted a need to evaluate whether CD4 testing at the POC (i.e. at the patient serving healthcare facility) should be incorporated into the South African public healthcare sector's HIV diagnostic service provision model. One challenge associated with the management of HIV in the country is the relatively large percentage of patients that are lost to follow-up at various points in the HIV treatment process. There is extensive evidence that testing CD4 levels at the POC (rather than in a laboratory, as is the current practice) reduces the percentage of patients that are lost to follow-up before being initiated onto ART. Therefore, though POC CD4 testing is more expensive than laboratory-based CD4 testing, the use of this technology in South Africa should be investigated for its potential to positively influence health outcomes. In this research, a multi-objective location science model is used to generate scenarios for the provision of CD4 testing capability. For each scenario, CD4 testing provision at 3 279 ART initiation facilities is considered. For each facility, either (i) a POC device is placed at the site; or (ii) the site's testing workload is referred to one of the 61 CD4 laboratories in the country. To develop this model, the characteristics of eight basic facility location models are compared to the attributes of the real-world problem in order to select the most suitable one for application. The selected model's objective, assumptions and inputs are adjusted in order to adequately model the realworld problem. The model is solved using the cross-entropy method for multi-objective optimisation and the results are verified using a commercial algorithm. Nine scenarios are selected from the acquired Pareto set for detailed presentation. In addition, details on the status quo as well as a scenario where POC testing is used as widely as possible are also presented. These scenarios are selected to provide decision-makers with information on the range of options that should be considered, from no or very limited use to widespread use of POC testing. Arguably the most valuable contribution of this research is to provide an indication of the optimal trade-off points between an improved healthcare outcome due to POC CD4 testing and increased healthcare spending on POC CD4 testing in the South African public healthcare context. This research also contributes to the location science literature and the metaheuristic literature.
Author: Louzanne Oosthuizen
Institution: Stellenbosch University
Language: English
Field: Decision Sciences
Domain: Social Sciences
Open Access status: green
Funder: Universiteit Stellenbosch
OpenAlex ID: W776800601
