Особенности регулирования температурных режимов установок воздушного охлаждения газа для различных условий сезонной эксплуатации
Year: 2012
Type: article
Abstract: Using K-drive allows to realize optimum modes of cooling not only by season operation depending on the corresponding average temperature of external air, but also and within the framework of operation GACI for separate month or during day. The analysis shows, that as a result of using K-drive for one of CS «Gazprom transgaz Yugorsk» Ltd. in comparison with discrete regulation the opportunity of annual economy with the current changes of temperatures of atmospheric air makes near 2500 MW per hour, that on 25 % more than annual economy for monthly average estimated temperatures.
Source: Omsk Scientific Bulletin
Author: Январёв Игорь Анатольевич
Language: Russian
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond