Polymer Lab-on-a-chips from Micro Blood Sampling to Immunoassay for Point-of-Care Testing of Neonates and Pediatrics in Intensive Care Unit
Year: 2013
Type: article
Abstract: The objective of this research is to develop a point-of-care testing (POCT) infrastructure from a micro blood sampling system to a sample-to-answer immunoassay lab-on-a-chip, which is based on the full characterizations of microfluidic immunoassay performance on polymer microchannels, for intensive care of neonates and pediatrics in ICU.In order to achieve the research objective, three polymer lab-on-a-chips from micro blood sampling to immunoassay have been designed, fabricated, and characterized for the POCT of neonates and pediatrics in ICU.The three polymer lab-on-a-chips are: (a) a new micro blood sampling system for minimizing iatrogenic blood loss; (b) a polymer spiral microchannel for microfluidic immunoassay; and (c) a sample-to-answer immunoassay lab-on-a-chip for a POCT platform.First, a new micro blood sampling system has been designed, fabricated, and characterized for providing micro-volume of blood to reduce iatrogenic blood loss from the catheterized neonates and pediatrics in ICU.In order to further reduce the blood loss during the sampling procedures, the system was designed for saving a discard blood, which is the initial volume of the sampled blood to be discarded as mixed with medication, to be returned to the patients.This can be done by having a closed structure that also decreases the risk of infection during the sampling procedures.In addition, the system was designed to have compatibility with the blood sampling procedures in the current clinical settings.As a result, the new micro blood sampling system can safely aspirate a micro volume of blood for the subsequent analysis in the lab-on-a-chip systems with minimal blood loss from the neonates and pediatrics in the ICU.2.5.1 Structural Analysis of the System 2.5.1.1Fluid leakage evaluation 2.5.1.2Optimization of passive valve width 2.5.1.3Consistency of the sampling volume 2.5.2Operational Analysis on the Sampling Procedures 2.5.2.1 Blood flow rate evaluation 2.5.2.2 Gas bubble generation evaluation 2.5.3Sampling Analysis on the System 2.5.3.1 Hemolysis evaluation from sampled blood 2.5.3.2Sample cross-contamination evaluation 2.6 Conclusion Chapter 3. Characterization of polymer spiral microchannels for the microfluidic immunoassay of thyroid stimulating hormone 3.1
Author: Wooseok Jung
Institution: University of Cincinnati
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W8599787