Development of Wavelength-Dispersive X-ray Spectrometer for a Conventional Analytical Transmission Electron Microscope
Year: 2006
Type: article
Abstract: Characterization with nm-scale spatial resolution is important for developments of new functional materials.Recently, Terauchi et al. [1][2][3] constructed a compact wavelength-dispersive X-ray spectrometer, referred as the original spectrometer, for a transmission electron microscope (TEM) and succeeded to obtain a density of states (DOS) of the valence band with an energy resolution of better than 1 eV by using a TEM.It implies that the DOS of the valence band (by X-ray emission spectroscopy: XES) and the conduction band (by electron energy-loss spectroscopy: EELS) can be obtainable from a specified small specimen area based on a transmission electron microscopy [4].Furthermore, the spectrometer dose not disturb the spatial resolution of a TEM, because it does not have a moving mechanism as in a case of WDS spectrometers of EPMA.We have started a project to renew the WDS spectrometer to attach to a conventional analytical TEM.Basic concept of the first spectrometer (high energy-dispersion version) is the same as that of the original one.It composed of 1) three varied-line-spacing (VLS) gratings, 2) a back-illumination type CCD detector and 3) X-ray collection mirrors.The measurable energy range is from 60 to 1200 eV.Compared to the original spectrometer, energy dispersion in an energy range of 60-400eV was improved by about two times.This first spectrometer is different from the original one in the take off angle of X-ray to measure.The original one was designed to measure X-rays emitted in almost horizontal direction.As a result, a specimen always has to be tilted more than 20 deg.for measurements.It is not convenient for a conventional analytical TEM.Thus, this new instrument is designed to measure the X-ray in the direction with an angle of elevation of about 35 deg.A specimen tilt for XES measurements is no more needed.The spectrometer is firstly installed in a TEM of JEM2010 as shown in FIG. 1.A silicon L-emission (valence bands→L 2,3 -shell) spectrum obtained by the first spectrometer is shown in FIG. 2. The spectrum represents the DOS of the valence bands with s-symmetry showing peak structures labeled by symmetry characters of L2', L1, X4 and L3'.The second WDS spectrometer is designed to cover an energy range of 60-1200 eV by using newly designed two VLS gratings.The energy dispersion of the spectrometer is designed smaller than that of the first spectrometer to obtain a larger collection angle, because of an extremely small emission efficiency of the soft-X-ray region to measure.Figure 3 shows a
Source: Microscopy and Microanalysis
Institutions: Tohoku University, Japan Atomic Energy Agency, JEOL (Japan)
Language: English
Subfield: Surfaces, Coatings and Films
Field: Materials Science
Domain: Physical Sciences
Open Access status: bronze
OpenAlex ID: W2012489827