Abstract: Enhancing the early detection of new therapies that are likely to carry a safety liability in the context of the intended patient population would provide a major advance in drug discovery. Microphysiological systems (MPS) technology offers an opportunity to support enhanced preclinical to clinical translation through the generation of higher-quality preclinical physiological data. In this review, we highlight this technological opportunity by focusing on key target organs associated with drug safety and metabolism. By focusing on MPS models that have been developed for these organs, alongside other relevant in vitro models, we review the current state of the art and the challenges that still need to be overcome to ensure application of this technology in enhancing drug discovery.
Institutions: AstraZeneca (United Kingdom), AstraZeneca (United States), Academic Center for Dentistry Amsterdam, University of Amsterdam, Amsterdam UMC Location Vrije Universiteit Amsterdam, University of Central Florida, AstraZeneca (Sweden), Karolinska Institutet, Emulate (United States), Medicines and Healthcare products Regulatory Agency, Universitätsmedizin Göttingen, German Centre for Cardiovascular Research