Post protection behavior of wooden wall and floor construction completely filled with glass wool
Year: 2010
Type: report
Abstract: This report presents a design method for post-protection behaviour of glass wool insulation in timber-frame assemblies.It is based on non-load-bearing small-scale tests at SP Trätek and full-scale tests at TÜV Estonia of standard fire exposure in accordance with EN 1363-1.Recession of glass wool insulation was measured during tests as a basic parameter of the described method.According to the method described in this report, the fire resistance of glass wool-insulated walls and floors should be calculated in the same way as for stone wool-insulated structures, using existing rules during the protected phase.The new design model takes into account the delay of charring along the wide sides of studs, although recession of glass wool occurs during the post-protection phase after the failure of the cladding.After complete recession of the glass wool insulation, the design procedure is similar to that for floor and wall assemblies with void cavities.The residual cross-section shape is treated as trapezoid.Calculation of load-bearing capacity requires not only the residual cross section to be taken into account, but also the reduced material properties of heated wood.The reduced cross-section method with zero-strength layer or reduced properties method should be used for structural design.
Author: Alar Just
Language: English
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2886198544