Year: 2021
Type: review
Study design: Systematic Review
Abstract: INTRODUCTION: There is evidence to suggest that blood viscosity (BV) is involved in several pathological processes. In this review, we evaluated the different methods of BV acquisition, analyzing the sample storage time, the storage temperature, the acquisition time, the acquisition temperature, sample volume, and shear rates, in order to standardize this technique. METHODS: We selected 50 articles with methods of obtaining BV, evaluating pathologies through BV, comparing rheological equipment, monitoring, and regulating BV. RESULTS AND CONCLUSION: Measurements should be obtained as soon as possible, to reduce hemorheological changes. It is necessary to refrigerate them at 4°C when the storage time is long. The acquisition time is related to the equipment used. BV measurements at 37°C will represent the real BV in vivo more faithfully. In order to understand the BV phenomena, the shear rates must be between 0.1 and 1000 s-1. There is a wide variety of equipment available for measuring the BV.
Source: European Journal Of Haematology
DOI: 10.1111/ejh.13594
Authors: Marcel Valério de Arruda, Alana Cruz Silva, José Carlos Fernandes Galduróz, Ruth Ferreira Galduróz
Language: English
Subfield: Hematology
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
OpenAlex ID: W3128765303