Abstract: I thank Drs Burnell and de Silva for their interest in my letter in which they ask which makes of laryngeal masks are available in my department, and what method of cuff inflation I use. As my department operates on three sites we use three makes: the disposable LMA-Unique™ and re-usable laryngeal mask airway – both from Intavent (Intavent Orthofix, Maidenhead, UK), and the disposable Ambu laryngeal mask airway (Ambu International, Basingstoke, UK). My practice changed after carrying out a series of audits of re-usable laryngeal mask airways [1], to those recommended by Asai and Brimacombe [2], which was the method utilised in the case using the gel pad but with a disposable Intavent Orthofix mask. The disposable laryngeal mask airways are less compliant than the re-usable ones, but they are thermoplastic and therefore become more compliant after a few minutes in the pharynx. With any laryngeal mask airway the chance of an airway leak is reduced a few minutes after induction as the patient settles and the mask moulds to the pharynx and also as the pharyngeal wall moulds to the cuff. In addition to the usual measures of reduced tidal volume, increased respiratory rate and an I : E ratio of 1 : 1 to reduce peak airway pressure in the patient using the gel pad, I also used a muscle relaxant to reduce chest wall compliance and therefore peak airway pressure, a method I find particularly useful in larger patients. It is possible that reducing the muscle tone of the pharyngeal muscles on the laryngeal mask cuff might tend to increase the possibility of a leak. It is difficult to know which factor is more prevalent. I agree that using a size 6 laryngeal mask may be another solution to the problem, but unfortunately this size was not available to me. When using a laryngeal mask airway it is useful to understand the pressure–volume relationship of the cuff. As it is inflated (after complete deflation) the air initially simply takes up the space in the cuff. When inflated by about 10 ml less than the maximum recommended volume, the cuff assumes a rounded shape. After this point, with any further inflation the material of the cuff stretches and the pressure rises much more steeply. If a cuff is already over-inflated at the beginning of the case, nitrous oxide diffusion into the cuff further exaggerates this pressure rise, reaching pressures of 250 mmHg, as I discovered in my study [1]. Since then I have monitored cuff pressure and volume in about 1500 patients, in 304 of whom disposable laryngeal mask airways were used. In the majority of these disposable airways, the cuff pressure was between 20 and 40 mmHg. Even using nitrous oxide, the pressure rises were less than 5 mmHg except in long cases, in which it only increased by up to 20 mmHg. Drs Burnell and de Silva also report difficulty preventing an airway leak in paediatric patients with the disposable laryngeal mask airway. In small paediatric laryngeal mask airways, pressure rises are exaggerated compared with the larger adult masks. I have only two documented cases using disposable airways in children; a 9- and a 13-year-old, both weighing 37 kg, using a size 3 Ambu laryngeal mask, neither of which had a leak with a cuff pressure of less than 30 mmHg. Interestingly, in two other 13-year-old patients weighing 50 and 57 kg, ventilated through a size 3 re-usable laryngeal mask airways, I was not able to prevent an airway leak with cuff pressures up to 90 mmHg. On changing to a size 4 laryngeal mask airway in each case, a leak was easily prevented with cuff pressures of only 20 mmHg. I realise that some manufacturers recommend a size 4 in 50–70 kg patients, but perhaps in smaller paediatric patients, if a seal cannot be obtained without resorting to high cuff volumes and pressures, another solution would be to use a larger size of laryngeal mask even if it falls outside the recommended weight range for that mask. If a leak still remains, I would suggest testing whether light external manual pressure on both sides of the larynx prevents the leak and, if so, a gel pad could be used, as recommended in my letter.
Source: Anaesthesia
Author: R. Lenoir
Institution: Portsmouth Hospitals NHS Trust
Language: English
Subfield: Anesthesiology and Pain Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
OpenAlex ID: W4256734371