Abstract: The 6-UPRU Stewart platform is affected by the passive screw effect of UPRU limbs, introducing extra axial rotation and limb-length deviation and deteriorating motion accuracy. Current investigations lack sufficient analysis of this phenomenon, while existing equivalent models ignore multi-angle coupling, and the valid range and difference features of such equivalent methods are poorly studied. This paper reveals the generation mechanism of the passive screw effect and develops a limb-length compensation model for high-precision kinematic analysis. Axial rotation characteristics at the upper and lower U-joints of UPS and UPRU limbs are analyzed, and a U-S joint equivalent replacement model is built considering the coupling of passive rotation angles. Validations are carried out via MATLAB calculations, ADAMS simulations, TOST tests, and Mann–Whitney U tests with Cohen’s d effect-size quantification. The axial rotation angles are essentially the passive screw angles. The proposed compensation effectively reduces systematic pose errors in numerical and virtual-prototype evaluations, demonstrating its potential for improving the kinematic accuracy of 6-UPRU Stewart platforms.