Work

Influence of Standing Waves on Impurity Analysis of Si(001) Wafer Using Commercially Available Total-Reflection X-Ray Fluorescence Analyzer

Year: 1993
Type: article
Abstract: In the analysis of trace impurities (on the order of 1010 atoms/cm2) on Si wafer surfaces using the commercially available total-reflection X-ray fluorescence analyzer, the X-ray fluorescence radiations are enhanced for the particular incident azimuth at which the evanescence beam penetrating into the Si wafer satisfies the Bragg condition. We investigated whether the enhancement of fluorescence radiation is due to the standing waves formed inside and outside the wafer surface. It is shown, using a sample which is intentionally contaminated with Zn, that the intensity enhancement is not directly connected with this phenomenon.
Language: English
Subfield: Radiation
Open Access status: bronze
OpenAlex ID: W2007753978
FWCI: 1.01
Cites: 5
Cited by: 7
Related to: 10